Air Pollution Monitoring Instruments

Offering you a complete choice of products which include respirable dust sampler, multi sampler, research microscope, stack sampler, biological incubator and benzene sampler.

Respirable Dust Sampler

Respirable Dust Sampler
  • Respirable Dust Sampler
Get Best Quote
Approx. Price: Rs 50,000 / PieceGet Latest Price

Product Details:

Flow Rate0.9 - 1.4 m3 /min free flow
Sampling Time28 Hours (maximum)
Sampling Time Record0 to 9999.99 hrs. Recorded on a Time Totalizer
Power220 V, Single Phase, 50Hz
Size770 x 418 x 340mm
Weight35 Kg
WarrantyOne year

The APS 113 NL uses an Indian brushless, continuous rated induction motor driven blower to significantly reduce equipment downtime, maintenance efforts and inconvenience to community. This new improved PM 10 sampler avoids problems arising due to frequent brush wear and limited armature life of blowers used in earlier models.


Features:

  • Significantly reduced noise as compared to most PM 10 instruments in the market.
  • Blower with in-built thermal cut-off eliminating the need for a stabilizer.
  • Brushless blower reduces equipment downtime and maintenance effort.
  • Lockable top cover and gaseous attachment.
  • Improved cabinet design which is more sturdy and durable with SS hardware.
  • Electromagnetic Interference (EMI) to TVs totally eliminated
Request
Callback


Additional Information:

  • Item Code: APS-113NL
Yes! I am Interested

Multi Sampler

Multi Sampler
  • Multi Sampler
Get Best Quote
Approx. Price: Rs 80,000 / PieceGet Latest Price

Product Details:

Minimum Order Quantity01 Piece
Power SourceElectronic
Flow Rate1.2 m3/hr
Power220 V, Single Phase, 50Hz
WarrantyOne year
Dimension610x535x115 mm

APS-500 PM 10/PM2.5 Sampler introduction of instrumentThe main component of Model APS-AM-500 PM10/PM2.5 sampler is constituted of high finished anodized two impactors which are a fitted parallel to each other in the sampler for PM2.5 as well as PM 10 measurement simultaneously. Impactor named as WINS Impactor (due to its shape of well) PM10 impactor measures all particles from air stream having size greater than 10 microns while 2nd impactor constitute of PM impactor which separate particles size lesser than 10 microns and and direct this to the lower par through a inlet pipe with PM 2.5 Impactor attached in its lower part measures particles with 10- 2.5 micron size. Both these impactor are modular in design and placed parallel and get same air partially directed in both the impactors together as per requirement. Impactors are configured for PM10 sampling and for PM2.5 sampling simultaneously.Design of both impactors are adopted from published USEPA design. Thus COMPLETE ENVIRONMENTAL SOLUTIONS designed PM10 and PM 2.5 WINS impactor are dimensionally traceable to standard YSEPA designs. A schematic diagram is shown in figure where all assemblies as Model CES-AM-500 and inter connection are visible.Design of impactors are for air flow rate of 1m3/hr or 16.7lpm. This flow rate required tobe constant at 16.7+_ 5% Model CES-AM-500 uses an rotary vane oil-free pump that produce needed suction. A critical flow control orifice for maintaining constant flow rate at 16.7lpm through out sample duration. To measure and totalize the volume of air passed through the filter in both the impactors at prevailing atmospheric temperature and pressure two different dry gas meter are fitted between the pump and both the filter adopter of each impactor.Design of the Model CES-AM-500 Sampler has been made such that suction pump assembly heat to not influence the temperature of filter on which PM2.5 dust is accumulating, Dry gas meter has been fitted in parallel. Two cabinets have been made one for pump unit where Timer is fitted to automate operation of sampler at decided time and another cabinet hold DGMs and Impactor assembly. Further to give actual on time of the sampler a Time Totalizer has been incorporated in circuit.A circular Omni directional inlet has been designed and fitted on top of the PM10impactor. Design of inlet has been made simpler and such that ambient dust reaching to PM10 impactor without hitting any surfaces of sampler in flow stream.
Request
Callback
Yes! I am Interested

Research Microscope

Research Microscope
  • Research Microscope
Get Best Quote
Approx. Price: Rs 25,000 / PieceGet Latest Price

Product Details:

Magnification4x,10x, 40x
Power (Volt)220
Weight (Kilograms)2.5 kg
Power SourceElectric
Size115mm x 125mm

Description:
  • (RESEARCH INCLINED MONOCULAR MICROSCOPE) (HR-1) with triple quadruple revolving nose piece adjustments below stage and with iris detachable graduated mechanical stage and straight tube for photomicrograph complete with light arrangement along with the following eye piece: 15x, 10x,15x,any two objectives : 10X, 45X& 100X (oil immersion)
  • (RESEARCH INCLINED BINOCULAR MICROSCOPE) (HR-1) with triple quadruple revolving nose piece adjustments below stage and with iris detachable graduated mechanical stage and straight tube for photomicrograph complete with light arrangement along with the following eye piece: 15x, 10x,15x,any two objectives : 10X, 45X& 100X (oil immersion)
  • (RESEARCH INCLINED TRINOCULAR MICROSCOPE) (HR-1) with triple quadruple revolving nose piece adjustments below stage and with iris detachable graduated mechanical stage and straight tube for photomicrograph complete with light arrangement along with the following eye piece: 15x, 10x,15x,any two objectives : 10X, 45X& 100X (oil immersion)
Request
Callback
Yes! I am Interested

Stack Sampler

Stack Sampler
  • Stack Sampler
Get Best Quote
Approx. Price: Rs 60,000 / SetGet Latest Price

Product Details:

Minimum Order Quantity01 Set
Temperature Range600 Deg C
Stack Velocity Range3 to 60 m/sec
Digital Clock0-60 Minutes
Size28 mm 1D x 100 mm
NozzlesSet of 3 stainless steel nozzles.

Specification:
  • Rota meter : Acrylic body rotameter with 2% FSD accuracy, 0-30 LPM for particulate and 0-3 lpm for gases.
  • Sampling Probe : Made from SS 304 tube, 0.6 length extend able to 1.2 m.
  • Filter Holder :Fabricated from SS 304 tube suitable to hold either cellulose filtration thimble or glass micro fiber thimble.
  • Sampling Train :1 No. of 240 ml capacity and 3 No. of 120 ml capacity borosilicate glass impingers accommodated in ice tray. placed on the rear side of instrument.
  • Vacuum Pump :Mono block rotary Vane type, oil lubricated, .05 HP single phase motor (230) with more than 50 lpm free flow capacity.
Request
Callback
Yes! I am Interested

Biological Incubator

Biological Incubator
  • Biological Incubator
Get Best Quote
Approx. Price: Rs 25,000 / UnitGet Latest Price

Product Details:

Capacity (Litre)250 Litre
Automation Type Automatic
Phase3 Phase
Power (Watt)1000 W
Voltage (Volt)220V, 50Hz,
Dimensions (millimetre)480x490x1070 mm
Weight (kg)147 kg

Request
Callback
Yes! I am Interested

Benzene Sampler

Benzene Sampler
  • Benzene Sampler
  • Benzene Sampler
Get Best Quote
Approx. Price: Rs 25,000 / PieceGet Latest Price

Product Details:

Minimum Order Quantity01 Piece
Power SourceElectric
Temperature Range0 to 50 Degree C
Noise65Db(A)
ApplicationLab, Clinic, Hospital

The increasing general awareness of atmospheric air pollution and its serious impacts of pollutants and hazards to the health and well-being of industrial workers has resulted in greater stress on accurate, reliable and frequent assessment of work space pollution and worker-exposure. The data so generated are needed for corrective measures to safe guard the workers as per Factory act 1948 and amendment in 1986-87.

Benzene in high concentrations has narcotic effects similar to toluene and other aromatics. Benzene is a myclotoxicant known to suppress bone marrow cell proliferation and to induce hematologic disorders in humans and animals. Chronic exposure to benzene leads to aplastic anemia, and may lead to leukemia after 6 months to 6 years of chronic exposure. Benzene exposure can cause chromosomal aberrations in animals and humans. Chronic benzene exposure has also been associated with lung cancer in epidemiological studies. Benzene is classified as a human carcinogen by American Conference of Governmental Industrial Hygienists (ACGIH) and International Agency for Research on Cancer (IARC).Benzene is classified as a suspected human carcinogen by OSHA.A risk assessment for benzene exposure performed by Rinsky et al., reported that a worker exposed to 10 ppm benzene for 40 years was 155 times more likely to die from leukemia than an unexposed worker. A worker exposed to 1 ppm benzene was 1.7 times more likely to die from leukemia than an unexposed worker.IARC has published a risk assessment showing that workers exposed to a 10 ppm chronic exposure, had an increase of 14-140 leukemia cases per 1000 people above the rate for an unexposed worker. For 1 ppm chronic exposure, there was an increase of 1.4-14 cases per 1000 above the rate for an unexposed worker.The skin notation cited in the TLV is based on the skin absorption rate of 0.05% when neat benzene is applied to the skin, indicating benzene exposures through skin absorption can be significant

Our Benzene sampler is based on the method of The collection of benzene using charcoal tubes (SKC lot 107) was evaluated in OSHA Method 12.1., method no 1005. Active samples are collected by drawing workplace air through charcoal tubes with personal sampling pumps. Diffusive samples are collected by exposing either SKC 575-002 Passive Samplers or 3M 3520 Organic Vapor Monitors (OVM) to workplace air. Samples are extracted with carbon disulfide and analyzed by GC using a flame ionization detector (FID).

APS-212 BENZENE SAMPLER uses a small light weight battery operated pump to draw air through and through charcoal tube filled with activated charcoal that is suitable absorption of VOC and benzene, While the Carbon monoxide can be monitored through electrochemical sensor and its reading is displayed on the screen of CO monitor.

VOC Samples are collected with 7-cm × 4-mm i.d. × 6-mm o.d. glass sampling tubes packed with two sections of charcoal. The front section contains 100 mg and the back section contains 50 mg of charcoal. The sections are held in place with glass wool and polyurethane plugs. Record sample air volume (liters), sampling time (minutes) and sampling rate (mL/min) for each sample


Rechargeable batteries have been used with sufficient storage to operate the system for 16 hours making it easier to compare workers dose to the TLV levels specified.

A separate charger is provided with APS-212 to recharge the batteries overnight.

Request
Callback
Yes! I am Interested

COD Digester

COD Digester
  • COD Digester
Get Best Quote
Approx. Price: Rs 22,000 / PieceGet Latest Price

Product Details:

ApplicationLaboratory Use
Power SourceElectric
MaterialStainless Steel
Voltage220 V
Dimension230 mm x 310 mm x 140mm